Home l About Us l Contact Us 

800 875-3067

 

 

  We Accept Credit Cards 

 MasterCard

Visa

American Express

 

Standard Trash Chutes


Royal-Pak maintenance free direct feed trash chutes are fully factory assembled with all vertical seams welded and tapered to allow easy slip joint assembly in the field.

 


No door interlocks to fail!  
No mechanized baffle to malfunction!  No electronic component to fail!

·   All Materials 16 Gauge Galvanized (aluminized) Steel

·    All Exterior Seams Welded

·    Custom Door Throat Opening

·    Bottom Hinged Stainless Steel Intake Doors With Hydraulically Controlled Self-Closing and Latching Mechanism (code compliant) UL “B”

·     Ό” X 2” Steel Floor Supports

·    UL “B” Rated 15” x 15” Side Hinge Access Door

·    Chute Sanitizing Unit Located Above Top Intake Door, Ready for Connection to Building Water Supply

·    Sprinkler Heads Ready For Connection at Alternate Floors

·    Explosion Vent Cap On Roof with flat or curb flashing

·    Spray On Sound deadening compound applied to external walls of standard  Bi-Pod and Tri-Pod chutes and as an option on Trash Chute

 

Options:

·    Two & Three Compartments for Recycling
(Bi-Pod & tri Pod Chutes)

·    Sound Deadening (Spray-On Or Wrap)

·    Vibration Isolation Pads

·    Door and Throat Extensions

·    Custom Chute Sizes

·    Custom Door and Throat Openings 

 


SPECIFICATIONS: “TRASH CHUTE”

Standard trash chute waste and recycling system as manufactured and installed by Royal-Pak Systems Inc. (201) 569-8888. This system must be provided by a firm specializing in the fabrication and installation of such work for at least a five (5) year period. Chute shall be 24” in diameter and shall be fabricated of 16 gauge aluminized or galvanized steel. Chute riser shall be welded and slip jointed construction with no interior fasteners of crimped joints. Contractor shall provide plumb floor openings of 28” x 28”. Intake doors to be 15” wide x 18” high, noiseless, self closing, self latching, bottom hinged, hand-operated with stainless steel finish and rubber safety baffles. Door shall bear Underwriters 1 ½ hour fire label. Chute transition shall deviate to suit discharge into compactor placement. It shall be field fabricated of 10 gauge steel and become an integral part of the compactor transition section. Floor support frames shall be fabricated of 3/16” steel x 2” flat bar. Sprinkler arrangements shall be supplied with corresponding openings in the chute, at the top intake level and alternate floors beneath, to be connected to the building sprinkler system by a licensed plumber. The sprinkler pendant shall be located within the throat section of the trash duct, and shall be protected by a 16 gauge galvanized shield. The chute shall be equipped above the top intake door with a wash down sanitizing system, requiring connection by a licensed plumber to a hose thread connection. The sanitizing system shall be piped within the chute to provide an even spray into the trash section of the chute. The chute shall penetrate the roof a minimum of 4’-0” above the roof slab with a vent cap and curb or flat flashing. Note: When chute extends through roof and is next to machine room, use 90* offset with 24” x 24” louver in lien of vent cap (Height is over 6’0”) bottom of louver is 4’0”.

Compactors Specs Sheet

 

 

Royal Pak Systems  206 Park St, Hackensack, NJ 07602 | 201.569.8888 Fax: 201.569.0808 | Email: info@royalpaksystems.com